Medical Device Penetration Testing
Medical device penetration testing across Europe: wireless, firmware and safety-impact attacks tested by hand for MDR and FDA readiness. Fixed price.
Medical device penetration testing carries a stake no other product test does: a vulnerability here is not just data at risk, it is a patient. We test infusion pumps, monitors, implantable and connected diagnostic devices the way an attacker would, across the firmware, the wireless links and the hospital network they sit on, and give you evidence your regulator, your customers and your safety case all accept.
What medical device penetration testing actually covers
A connected medical device is a small computer that can affect a human body, and it usually lives on a network shared with everything else in a hospital. That combination makes it a serious target and a hard one to secure, because the same patch cycle that fixes a bug can also require re-validation of a life-critical function. Medical device cybersecurity penetration testing has to weigh every finding against patient safety, not just confidentiality, and that is the lens we bring to the whole engagement.
How we test a medical device
Every engagement is manual and safety-aware, run by an engineer experienced across hardware, firmware and wireless, working from a written scope agreed with your regulatory and clinical teams. Medical device pen testing is never reckless probing of a live unit; it is careful, staged testing on samples and test rigs, escalating only as the scope and the safety analysis allow.
Threat modelling and scoping
We start with the device’s intended use and its risk profile. A device that delivers a drug dose has a different threat model than one that only displays a reading, so we map the functions where a compromise would harm a patient and prioritise those. This aligns with the safety risk management your quality system already runs, and it keeps the test focused on what matters clinically rather than on a long list of low-consequence noise.
Hardware and firmware analysis
We examine the physical device for exposed debug interfaces, extract and analyse the firmware for hardcoded credentials, keys and vulnerable components, and test whether secure boot and the update mechanism actually prevent a modified image from running. A device that accepts unsigned firmware is a device an attacker can reprogram, and on a therapy-delivering unit that is a patient-safety finding, not just a security one.
Wireless and protocol testing
Connected devices talk over BLE, Wi-Fi or proprietary radio, and clinical systems talk HL7, DICOM and increasingly FHIR. We test pairing and authentication on the wireless links, attempt to intercept and inject commands, and probe the clinical protocols for tampering, replay and data exposure. Many devices trust any peer that can reach them, which is exactly the assumption an attacker exploits.
Network behaviour, exploitation and reporting
We assess how the device behaves on the hospital network, including whether it can be attacked laterally and whether it can be used as a pivot toward other systems. Where we find a real issue, we prove it on a test unit with reproduction steps, always stopping short of anything that could endanger a device in clinical use. You get the report within days, mapped to safety impact, with a live walkthrough and a free retest of the fixed device.
Vulnerabilities we routinely find in medical devices
The pressures of the sector, long product lifecycles, strict validation, and a historic focus on safety over security, produce a recognisable set of weaknesses.
Hardcoded and shared credentials
Service passwords, maintenance accounts and keys baked into the firmware, identical across every unit shipped, are a persistent finding. Extract them from one device and you have access to the entire fleet, including the back-end services the device authenticates to.
Unauthenticated wireless commands
Wireless interfaces that pair without real authentication, or accept commands from any nearby transmitter, let an attacker in radio range interact with the device. Depending on the product, that can mean reading patient data, changing a setting, or interfering with therapy, which is the scenario that makes headlines, triggers recalls and erodes clinical trust in the product.
Weak or absent update security
Devices that do not verify firmware signatures, or that allow rollback to a vulnerable version, can be reprogrammed by an attacker. Because medical devices stay in service for many years, an insecure update path is a long-lived risk that only grows as the underlying components age.
Exposed clinical protocols
HL7 and DICOM were designed for trusted networks and often run without authentication or encryption. On a flat hospital network, patient data crosses in the clear and messages can be tampered with, altering records or imaging. We test these interfaces for exposure, injection and manipulation, and show where authentication and encryption need to be added without breaking interoperability with the systems the device already talks to.
Outdated components and flat-network assumptions
Many devices run old operating systems and libraries that can no longer be patched easily, and are protected mainly by the assumption of a segmented network that hospitals do not always deliver. We identify the vulnerable components and test what an attacker achieves when that segmentation is absent, which is a realistic and common condition.
Want this tested on your own systems?
Free 20-minute scoping call, a fixed price with no hourly surprises, and a free retest once you fix what we find.
Compliance, standards and regulatory readiness
Medical device security is heavily regulated on both sides of the Atlantic, and our report is built to support your technical documentation and your submissions.
European regulation and standards
Under the EU Medical Device Regulation (MDR), cybersecurity is part of the essential requirements, and MDCG 2019-16 gives the specific guidance on how to meet it. We assess against IEC 62443 for the device as a system component, IEC 62304 expectations for the software lifecycle, and the connected-product baseline in ETSI EN 303 645 where it applies. The evidence slots into your safety and security risk management under ISO 14971.
FDA and international submissions
For products heading to the US market, the FDA premarket cybersecurity guidance expects a security risk assessment, a software bill of materials, and evidence of security testing. Our deliverables, including an SBOM with reachable-CVE analysis, are structured to support that submission and the equivalent expectations of other regulators.
Healthcare operations
For devices already deployed, the results also support IEC 80001 on IT-network risk management for medical devices and inform the hospital’s own segmentation and monitoring. Where the device or its cloud handles patient data, we test with GDPR obligations firmly in mind.
What you get from the engagement
A report that satisfies a regulator and guides an engineering team, written by people who understand both audiences.
- An executive summary for leadership, regulatory affairs and quality
- A technical report with each finding scored by CVSS, rated for patient-safety impact, and paired with exact reproduction steps
- A software bill of materials with reachable-CVE analysis for your submission
- Specific remediation advice balanced against re-validation effort and clinical function
- An attestation letter to support MDR, FDA, IEC 62443 or a customer review
- A live walkthrough with your engineering, security and regulatory teams, and a free retest of the fixed device
Everything is delivered under NDA, and any devices, firmware and data are handled securely and returned or destroyed on request.
Why manual, specialist testing is the only responsible choice
You cannot point a generic scanner at an infusion pump and learn anything that matters. Understanding whether an attacker can alter a dose, reprogram a device over the air, or tamper with a DICOM stream needs a person who works across hardware, radio and clinical protocols and who reasons in terms of patient harm, not just CVSS. Among medical device testing companies, the ones worth hiring are the ones who will handle a live-critical device with the care it demands and still find the flaw a real attacker would. We test on samples and rigs, prove impact without ever endangering a device in use, and hand you findings tied to safety and remediation you can actually validate. That is what medical device security testing has to be when a defect can reach a person, not just a database.
Pricing
Pricing depends on scope: the device’s complexity and risk class, whether hardware, firmware, wireless and companion apps are all in scope, and how many variants you need covered. Here is the shape of a typical European engagement.
| Engagement | What’s included | Timeline | Price |
|---|---|---|---|
| Essential | Single lower-risk device, firmware and wireless review, hardcoded-secret and update-integrity testing, report and free retest | 6–9 working days | from €3,000 |
| Standard | Connected device across hardware, firmware, BLE or Wi-Fi and clinical protocols, plus the companion app, with safety-impact analysis | 9–15 working days | €4,500–€12,000 |
| Advanced | High-risk or therapy-delivering device: deep hardware attacks, proprietary RF, cloud back end and full attack-chaining, mapped to safety cases | 15–25 working days | €12,000–€30,000 |
| Compliance add-on | SBOM deliverable and attestation for MDR/MDCG 2019-16, FDA premarket, IEC 62443 or IEC 62304 | with any tier | from €1,000 |
| Custom / device family | A full product line or platform across several devices, scoped after a free call | on scoping | custom |
Every engagement is fixed-price, quoted after a free 20-minute scoping call — no hourly surprises, and a retest is included. Get a fixed quote
FAQ
How much does medical device penetration testing cost?
How long does a medical device pen test take?
Will testing put a device or patient at risk?
Will this support our MDR or FDA submission?
Do you test the wireless and companion app as well as the device?
What makes you different from other medical device testing companies?
How many device samples do you need?
Is everything kept confidential?
Related services
Medical device manufacturers and connected-health teams preparing for MDR or FDA submission, a customer or hospital security review, or launch, who need their device’s cybersecurity and patient-safety exposure tested by specialists before it reaches a bedside.
Security you can prove
The same standard on every engagement, big or small.
Evidence, not opinions
Every finding ships with a reproduction and proof of concept — no vague "maybe vulnerable".
Humans over scanners
Certified engineers find the logic flaws and chained attacks automated tools walk straight past.
Fixed price, free retest
You know the cost up front, and verifying the fix is part of the deal — not a second invoice.
Ready to lock this down?
Free scoping call, fixed price, free retest. Tell us what you're running and we'll take it from there — usually within one business day.
Tell us what you're running
Scoping is free. We reply within one business day, and under 30 minutes for active incidents.